<!DOCTYPE article
PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.4 20190208//EN"
       "JATS-journalpublishing1.dtd">
<article xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" article-type="research-article" dtd-version="1.4" xml:lang="en">
 <front>
  <journal-meta>
   <journal-id journal-id-type="publisher-id">Actual problems in dentistry</journal-id>
   <journal-title-group>
    <journal-title xml:lang="en">Actual problems in dentistry</journal-title>
    <trans-title-group xml:lang="ru">
     <trans-title>Проблемы стоматологии</trans-title>
    </trans-title-group>
   </journal-title-group>
   <issn publication-format="print">2077-7566</issn>
   <issn publication-format="online">2412-9461</issn>
  </journal-meta>
  <article-meta>
   <article-id pub-id-type="publisher-id">64078</article-id>
   <article-id pub-id-type="doi">10.18481/2077-7566-2023-19-1-121-125</article-id>
   <article-categories>
    <subj-group subj-group-type="toc-heading" xml:lang="ru">
     <subject>ОРТОПЕДИЧЕСКАЯ СТОМАТОЛОГИЯ</subject>
    </subj-group>
    <subj-group subj-group-type="toc-heading" xml:lang="en">
     <subject>ORTHOPEDIC  DENTISTRY</subject>
    </subj-group>
    <subj-group>
     <subject>ОРТОПЕДИЧЕСКАЯ СТОМАТОЛОГИЯ</subject>
    </subj-group>
   </article-categories>
   <title-group>
    <article-title xml:lang="en">COMPARATIVE ASSESSMENT OF STATIC STRENGTH OF IMPLANT-ABUTMENT CONNECTIONS OF VARIOUS IMPLANT SHAPES</article-title>
    <trans-title-group xml:lang="ru">
     <trans-title>СРАВНИТЕЛЬНАЯ ОЦЕНКА СТАТИЧЕСКОЙ ПРОЧНОСТИ ИМПЛАНТАТ-АБАТМЕНТОВЫХ СОЕДИНЕНИЙ ИМПЛАНТАТОВ РАЗЛИЧНЫХ ФОРМ</trans-title>
    </trans-title-group>
   </title-group>
   <contrib-group content-type="authors">
    <contrib contrib-type="author">
     <name-alternatives>
      <name xml:lang="ru">
       <surname>Брагин</surname>
       <given-names>Евгений Александрович</given-names>
      </name>
      <name xml:lang="en">
       <surname>Bragin</surname>
       <given-names>Evgeniy Aleksandrovich</given-names>
      </name>
     </name-alternatives>
     <email>professor_bragin@mail.ru</email>
     <bio xml:lang="ru">
      <p>доктор медицинских наук;</p>
     </bio>
     <bio xml:lang="en">
      <p>doctor of medical sciences;</p>
     </bio>
     <xref ref-type="aff" rid="aff-1"/>
    </contrib>
    <contrib contrib-type="author">
     <name-alternatives>
      <name xml:lang="ru">
       <surname>Эльканов</surname>
       <given-names>Ахмат Аубекирович</given-names>
      </name>
      <name xml:lang="en">
       <surname>El'kanov</surname>
       <given-names>Ahmat Aubekirovich</given-names>
      </name>
     </name-alternatives>
     <email>aha9107@yandex.ru</email>
     <bio xml:lang="ru">
      <p>кандидат медицинских наук;</p>
     </bio>
     <bio xml:lang="en">
      <p>candidate of medical sciences;</p>
     </bio>
     <xref ref-type="aff" rid="aff-2"/>
    </contrib>
    <contrib contrib-type="author">
     <name-alternatives>
      <name xml:lang="ru">
       <surname>Долгалев</surname>
       <given-names>Александр Александрович</given-names>
      </name>
      <name xml:lang="en">
       <surname>Dolgalev</surname>
       <given-names>Aleksandr A.</given-names>
      </name>
     </name-alternatives>
     <email>dolgalev@dolgalev.pro</email>
     <bio xml:lang="ru">
      <p>доктор медицинских наук;</p>
     </bio>
     <bio xml:lang="en">
      <p>doctor of medical sciences;</p>
     </bio>
     <xref ref-type="aff" rid="aff-3"/>
    </contrib>
    <contrib contrib-type="author">
     <name-alternatives>
      <name xml:lang="ru">
       <surname>Сергеев</surname>
       <given-names>Юрий Андреевич</given-names>
      </name>
      <name xml:lang="en">
       <surname>Sergeev</surname>
       <given-names>Yuriy Andreevich</given-names>
      </name>
     </name-alternatives>
     <email>serg_yuriy@mail.ru</email>
     <bio xml:lang="ru">
      <p>кандидат медицинских наук;</p>
     </bio>
     <bio xml:lang="en">
      <p>candidate of medical sciences;</p>
     </bio>
     <xref ref-type="aff" rid="aff-4"/>
    </contrib>
    <contrib contrib-type="author">
     <name-alternatives>
      <name xml:lang="ru">
       <surname>Аванисян</surname>
       <given-names>Вазген Михайлович</given-names>
      </name>
      <name xml:lang="en">
       <surname>Avanisyan</surname>
       <given-names>Vazgen Mikhaylovich</given-names>
      </name>
     </name-alternatives>
     <email>avanvaz@yandex.ru</email>
     <xref ref-type="aff" rid="aff-5"/>
    </contrib>
   </contrib-group>
   <aff-alternatives id="aff-1">
    <aff>
     <institution xml:lang="ru">Ставропольский государственный медицинский университет</institution>
     <city>Ставрополь</city>
     <country>Россия</country>
    </aff>
    <aff>
     <institution xml:lang="en">Stavropol State Medical University</institution>
     <city>Stavropol</city>
     <country>Russian Federation</country>
    </aff>
   </aff-alternatives>
   <aff-alternatives id="aff-2">
    <aff>
     <institution xml:lang="ru">Ставропольский государственный медицинский университет</institution>
     <city>Ставрополь</city>
     <country>Россия</country>
    </aff>
    <aff>
     <institution xml:lang="en">Stavropol State Medical University</institution>
     <city>Stavropol</city>
     <country>Russian Federation</country>
    </aff>
   </aff-alternatives>
   <aff-alternatives id="aff-3">
    <aff>
     <institution xml:lang="ru">Ставропольский государственный медицинский университет</institution>
     <city>Ставрополь</city>
     <country>Россия</country>
    </aff>
    <aff>
     <institution xml:lang="en">Stavropol State Medical University</institution>
     <city>Stavropol</city>
     <country>Russian Federation</country>
    </aff>
   </aff-alternatives>
   <aff-alternatives id="aff-4">
    <aff>
     <institution xml:lang="ru">Ставропольский государственный медицинский университет</institution>
     <city>Ставрополь</city>
     <country>Россия</country>
    </aff>
    <aff>
     <institution xml:lang="en">Stavropol State Medical University</institution>
     <city>Stavropol</city>
     <country>Russian Federation</country>
    </aff>
   </aff-alternatives>
   <aff-alternatives id="aff-5">
    <aff>
     <institution xml:lang="ru">Ставропольский государственный медицинский университет</institution>
     <city>Ставрополь</city>
     <country>Россия</country>
    </aff>
    <aff>
     <institution xml:lang="en">Stavropol State Medical University</institution>
     <city>Stavropol</city>
     <country>Russian Federation</country>
    </aff>
   </aff-alternatives>
   <pub-date publication-format="print" date-type="pub" iso-8601-date="2023-05-22T22:04:31+03:00">
    <day>22</day>
    <month>05</month>
    <year>2023</year>
   </pub-date>
   <pub-date publication-format="electronic" date-type="pub" iso-8601-date="2023-05-22T22:04:31+03:00">
    <day>22</day>
    <month>05</month>
    <year>2023</year>
   </pub-date>
   <volume>19</volume>
   <issue>1</issue>
   <fpage>121</fpage>
   <lpage>125</lpage>
   <history>
    <date date-type="received" iso-8601-date="2023-04-27T00:00:00+03:00">
     <day>27</day>
     <month>04</month>
     <year>2023</year>
    </date>
   </history>
   <self-uri xlink:href="https://dental-press.ru/en/nauka/article/64078/view">https://dental-press.ru/en/nauka/article/64078/view</self-uri>
   <abstract xml:lang="ru">
    <p>На сегодняшний день вопрос оптимально-восстановительного протезирования на дентальных имплантатах является первостепенным в решении ряда клинически сложных случаев и выходит за рамки альтернативного лечения при полной и частичной адентии как на верхней, так и на нижней челюсти. При этом существенным фактором является понимание биомеханического поведения на уровне имплантат-абатментового соединения, так как оптимальное соединение на уровне имплантат-абатмент позволяет имитировать биофизическое поведение естественных зубов и обеспечить долговременную эксплуатацию ортопедических конструкций. Оптимальным методом оценки имплантат-абатментового узла является статический метод определения предела прочности. Определение предела осуществляется при помощи единоразового нагружения дентального имплантата в области имплантат-абатмент.&#13;
Целью исследования явилась оценка имплантат-абатментовой деформации разборных и неразборых конструкций абатментов дентальных имплантатов 4*10 цилиндрической и конусной форм, с определением предела их статической прочности.&#13;
Материалы и методы. Объектами исследования были выбраны дентальные имплантаты двух марок — цилиндрический имплантат ЛИКО М 4х10 и имплантат конусной формы ЛИКО М ДГ 4x10, предметом исследования явился предел прочности имплантат-абатментового узла разборной и неразборной конструкций абатментов. &#13;
Результаты. Осуществлены статические нагрузочные тесты с определением предела деформации узла имплантат-абатмент, со сравнительной оценкой прочности разборной и неразборной конструкций абатментов дентальных имплантатов различных форм. &#13;
Заключение. Проведенный сравнительный анализ статической прочности позволяет оптимизировать процесс ортопедического лечения на дентальных имплантатах с учетом максимальных пределов нагружаемых конструкций и осуществить равновесное распределение нагрузки.</p>
   </abstract>
   <trans-abstract xml:lang="en">
    <p>Nowadays the problem of optimal restorative prosthetics on dental implants is of paramount importance for solving a number of clinically difficult cases and extends beyond the alternative treatment at the complete and partial adentia both on the upper and lower jaws. An essential factor here is understanding of the biomechanical behaviour of the implant-abutment interface, because an optimal implant-abutment interface simulates the biophysical behaviour of natural teeth and ensures the long-term function of the prosthetic restoration. The optimal method for assessing the implant-abutment junction is the static tensile strength method. The limit is determined by performing a single loading of the dental implant in the implant-abutment area.&#13;
The aim of the study was to assess the implant-abutment deformation of demountable and non-demountable structures of the 4*10 cylindrical and cone-shaped dental implants with determination of their static strength limit.&#13;
Materials and methods. Two brands of dental implants have been chosen as the objects of research – cylindrical implant LIKO M 4x10 and cone-shaped implant LIKO M DG 4x10. A subject of the research is the ultimate strength of the implant-abutment unit of demountable and non-dismountable abutment design. &#13;
Results. Static loading tests with estimation of the deformation limit of the implant-abutment unit were carried out along with the comparative estimation of the strength of demountable and non-demountable abutment constructions of dental implants of various shapes. &#13;
Conclusion. The carried out comparative analysis of the static strength makes it possible to optimise the process of orthopaedic treatment on dental implants taking into account the maximal limits of the loaded structures and to carry out the equilibrium load distribution.</p>
   </trans-abstract>
   <kwd-group xml:lang="ru">
    <kwd>дентальный имплантат</kwd>
    <kwd>абатмент</kwd>
    <kwd>статические испытания</kwd>
    <kwd>конусный дентальный имплантат</kwd>
    <kwd>цилиндрический дентальный имплантат</kwd>
    <kwd>имплантат-абатментовый узел</kwd>
   </kwd-group>
   <kwd-group xml:lang="en">
    <kwd>dental implant</kwd>
    <kwd>abutment</kwd>
    <kwd>static testing</kwd>
    <kwd>conical dental implant</kwd>
    <kwd>cylindrical dental implant</kwd>
    <kwd>implant-abutment unit</kwd>
    <kwd>static test</kwd>
   </kwd-group>
   <funding-group>
    <funding-statement xml:lang="ru">Финансирование исследования осуществлялось из личных средств авторов.</funding-statement>
    <funding-statement xml:lang="en">Funding for the study was carried out from the personal funds of the authors.</funding-statement>
   </funding-group>
  </article-meta>
 </front>
 <body>
  <p></p>
 </body>
 <back>
  <ref-list>
   <ref id="B1">
    <label>1.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">ГОСТ Р ИСО 14801-2012. Стоматология. Имплантаты. Усталостные испытания для внутрикостных стоматологических имплантатов. - М. : ФГУП «СТАНДАРТ-ИНФОРМ», 2012. - 12 с.</mixed-citation>
     <mixed-citation xml:lang="en">GOST R ISO 14801-2012. Stomatologiya. Implantaty. Ustalostnye ispytaniya dlya vnutrikostnyh stomatologicheskih implantatov. - M. : FGUP «STANDART-INFORM», 2012. - 12 s.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B2">
    <label>2.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Мураев, А. А. Инновационная российская система дентальных имплантатов: разработка, лабораторные исследования и клиническое внедрение: специальность 14.01.14 &quot;Стоматология&quot; : диссертация на соискание ученой степени доктора медицинских наук / Мураев Александр Александрович. - Москва, 2019. - 294 с.</mixed-citation>
     <mixed-citation xml:lang="en">Muraev, A. A. Innovacionnaya rossiyskaya sistema dental'nyh implantatov: razrabotka, laboratornye issledovaniya i klinicheskoe vnedrenie: special'nost' 14.01.14 &quot;Stomatologiya&quot; : dissertaciya na soiskanie uchenoy stepeni doktora medicinskih nauk / Muraev Aleksandr Aleksandrovich. - Moskva, 2019. - 294 s.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B3">
    <label>3.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Цыганков Алексей Игоревич. &quot;Моделирование усталостного разрушения внутрикостных стоматологических имплантатов&quot; Модели, системы, сети в экономике, технике, природе и обществе, no. 3 (7), 2013, pp. 188-192.</mixed-citation>
     <mixed-citation xml:lang="en">Cygankov Aleksey Igorevich. &quot;Modelirovanie ustalostnogo razrusheniya vnutrikostnyh stomatologicheskih implantatov&quot; Modeli, sistemy, seti v ekonomike, tehnike, prirode i obschestve, no. 3 (7), 2013, pp. 188-192.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B4">
    <label>4.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Bayata F., Yildiz C. The effects of design parameters on mechanical failure of Ti-6Al-4V implants using finite element analysis. Eng. Fail. Anal. 2020;110:104445. doi: 10.1016/j.engfailanal.2020.104445.</mixed-citation>
     <mixed-citation xml:lang="en">Bayata F., Yildiz C. The effects of design parameters on mechanical failure of Ti-6Al-4V implants using finite element analysis. Eng. Fail. Anal. 2020;110:104445. doi: 10.1016/j.engfailanal.2020.104445.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B5">
    <label>5.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Duan Y., Griggs J.A. Effect of loading frequency on cyclic fatigue lifetime of a standard-diameter implant with an internal abutment connection. Dent. Mater. 2018;6:1711-1716. doi: 10.1016/j.dental.2018.09.001.</mixed-citation>
     <mixed-citation xml:lang="en">Duan Y., Griggs J.A. Effect of loading frequency on cyclic fatigue lifetime of a standard-diameter implant with an internal abutment connection. Dent. Mater. 2018;6:1711-1716. doi: 10.1016/j.dental.2018.09.001.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B6">
    <label>6.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">John W.N. Titanium Alloys for Dental Implants: A Review. Prosthesis. 2020;2:100-116.</mixed-citation>
     <mixed-citation xml:lang="en">John W.N. Titanium Alloys for Dental Implants: A Review. Prosthesis. 2020;2:100-116.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B7">
    <label>7.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Leon P.P., Bartolome J.F., Lombardia C., Pradies G. Mechanical fatigue behavior of different lengths screw-retained restorations connected to two designs prosthetic connection level. J. Oral Rehabil. 2019;46:747-755.</mixed-citation>
     <mixed-citation xml:lang="en">Leon P.P., Bartolome J.F., Lombardia C., Pradies G. Mechanical fatigue behavior of different lengths screw-retained restorations connected to two designs prosthetic connection level. J. Oral Rehabil. 2019;46:747-755.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B8">
    <label>8.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Perriard J., Wiskott W.A., Mellal A., Scherrer S.S., Belser U.C. Fatigue resistance of ITI implant-abutment connectors-a comparison of the standard cone with a novel internally keyed design. Clin. Oral Implants Res. 2002;13:542-549. doi: 10.1034/j.1600-0501.2002.130515.x.</mixed-citation>
     <mixed-citation xml:lang="en">Perriard J., Wiskott W.A., Mellal A., Scherrer S.S., Belser U.C. Fatigue resistance of ITI implant-abutment connectors-a comparison of the standard cone with a novel internally keyed design. Clin. Oral Implants Res. 2002;13:542-549. doi: 10.1034/j.1600-0501.2002.130515.x.</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B9">
    <label>9.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Qian L., Todo M., Koyano K. Effects of implant diameter, insertion depth, and loading angle on stress/strain fields in implant/jawbone systems. Int. J. Oral Maxillofac. Implants. 2009;24:877-886</mixed-citation>
     <mixed-citation xml:lang="en">Qian L., Todo M., Koyano K. Effects of implant diameter, insertion depth, and loading angle on stress/strain fields in implant/jawbone systems. Int. J. Oral Maxillofac. Implants. 2009;24:877-886</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B10">
    <label>10.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Sun, F., Lv, L. T., Cheng, W., Zhang, J. L., Ba, D. C., Song, G. Q., &amp; Lin, Z. (2021). Effect of Loading Angles and Implant Lengths on the Static and Fatigue Fractures of Dental Implants. Materials (Basel, Switzerland), 14(19), 5542. https://doi.org/10.3390/ma14195542</mixed-citation>
     <mixed-citation xml:lang="en">Sun, F., Lv, L. T., Cheng, W., Zhang, J. L., Ba, D. C., Song, G. Q., &amp; Lin, Z. (2021). Effect of Loading Angles and Implant Lengths on the Static and Fatigue Fractures of Dental Implants. Materials (Basel, Switzerland), 14(19), 5542. https://doi.org/10.3390/ma14195542</mixed-citation>
    </citation-alternatives>
   </ref>
   <ref id="B11">
    <label>11.</label>
    <citation-alternatives>
     <mixed-citation xml:lang="ru">Wang K., Geng J., Jones D., Wei X. Comparison of the fracture resistance of dental implants with different abutment taper angles. Mater. Sci. Eng. C. 2016;63:164-171. doi: 10.1016/j.msec.2016.02.015</mixed-citation>
     <mixed-citation xml:lang="en">Wang K., Geng J., Jones D., Wei X. Comparison of the fracture resistance of dental implants with different abutment taper angles. Mater. Sci. Eng. C. 2016;63:164-171. doi: 10.1016/j.msec.2016.02.015</mixed-citation>
    </citation-alternatives>
   </ref>
  </ref-list>
 </back>
</article>
